Also note, the general product suggestions address performance attributes for window walls and, secondarily, sliding operable windows. Note, architects will also need solar control products to meet SHGC requirements. The table below provides a general idea of the potential glazing solutions to meet U-factor requirements. What, roughly, will be required for glazing products to meet the U-factor requirements out-lined in ASHRAE 90.1-2019? A team gets a base fee, and then gets more or less than that based on building performance,” says LBL’s Selkowitz. “We have started to see performance-based contracts. However, some developers and building owners are also adding contract clauses to withhold a portion of the payment until verified performance goals have been met.
#Ashrae 90.1 2016 window u value driver
A big driver of this is outcome-based codes.
#Ashrae 90.1 2016 window u value code
… In the next code cycle, they are going to have performance requirements.”Ĭalls for verified performance will require project teams to prove their building lives up to energy and thermal performance targets after occupancy. “At first, there will be no requirement, just documentation. “In the New York City energy code, architects are going to have to make drawings that show all the thermal bridges with details that quantify transmissions,” says Dan Piselli, director of sustainability at FXCollaborative. Identifying and addressing the thermal bridges in a system will improve whole-system performance. Thermal bridging refers to the more thermally conductive-or thermally inefficient-sections or components of a system or wall. These new backstops are being enacted in New York City, Massachusetts, and Washington state, but they will not be part of ASHRAE 90.1-2019 or 2021 IECC.Īlso on the horizon are thermal bridging requirements. These backstops can limit how much of the HVAC, lighting, and hot water systems can be used as a trade-off against envelope and window area components. There are two main code trends to watch: envelope backstops and verified performance requirements.Įnvelope backstops require a minimum level of envelope performance, no matter what else is done in the building. The new code also includes stronger daylighting requirements, including demand for more controls and toplighting.
In general, the new code marks a push for improved framing, warm-edge spacers, argon gas fill, and fourth-surface low-e coatings.
If products currently meet the requirements for one zone, it will not be too difficult to push that product into the next zone. In many cases, this creates roughly a “zone shift” between the 20 versions-what was required in Zone 7 will move to Zone 6, Zone 6 to Zone 5, etc. Among the updates include another 5–17 percent reduction in U-factor. The newest version of ASHRAE 90.1-2019 was approved in October 2019, and it continues its trend toward increased energy performance in glass and glazing systems.
#Ashrae 90.1 2016 window u value windows
In the previous 15 years alone, ASHRAE 90.1 U-factors for windows reduced between 20 and 60 percent, depending on the climate zone. High-performance glass and glazing solutions typically meet or exceed energy code requirements and/or health and safety codes and requirements, but it is important to be aware of the current codes when specifying buildings.Įach new edition of the baseline energy codes brings increasingly stringent requirements for windows, particularly in terms of thermal performance. Translating Code Requirements to Glazing System SolutionsĪs technology advances, energy codes are revised and updated to ensure that buildings are not only safe for occupants but also provide as little impact as possible on the environment.